1.
Sci Rep ; 14(1): 8371, 2024 04 10.
Article En | MEDLINE | ID: mdl-38600217

Cardiac resynchronisation therapy (CRT) improves prognosis in patients with heart failure (HF) however the role of ABO blood groups and Rhesus factor are poorly understood. We hypothesise that blood groups may influence clinical and survival outcomes in HF patients undergoing CRT. A total of 499 patients with HF who fulfilled the criteria for CRT implantation were included. Primary outcome of all-cause mortality and/or heart transplant/left ventricular assist device was assessed over a median follow-up of 4.6 years (IQR 2.3-7.5). Online repositories were searched to provide biological context to the identified associations. Patients were divided into blood (O, A, B, and AB) and Rhesus factor (Rh-positive and Rh-negative) groups. Mean patient age was 66.4 ± 12.8 years with a left ventricular ejection fraction of 29 ± 11%. There were no baseline differences in age, gender, and cardioprotective medication. In a Cox proportional hazard multivariate model, only Rh-negative blood group was associated with a significant survival benefit (HR 0.68 [0.47-0.98], p = 0.040). No association was observed for the ABO blood group (HR 0.97 [0.76-1.23], p = 0.778). No significant interaction was observed with prevention, disease aetiology, and presence of defibrillator. Rhesus-related genes were associated with erythrocyte and platelet function, and cholesterol and glycated haemoglobin levels. Four drugs under development targeting RHD were identified (Rozrolimupab, Roledumab, Atorolimumab, and Morolimumab). Rhesus blood type was associated with better survival in HF patients with CRT. Further research into Rhesus-associated pathways and related drugs, namely whether there is a cardiac signal, is required.


Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Middle Aged , Aged , Stroke Volume , Ventricular Function, Left , Cardiac Resynchronization Therapy/adverse effects , ABO Blood-Group System , Treatment Outcome
2.
Heart Rhythm ; 2024 Jan 28.
Article En | MEDLINE | ID: mdl-38286244

BACKGROUND: Focal and rotational activations have been demonstrated in atrial fibrillation (AF), but their relationship to each other and to structural remodeling remains unclear. OBJECTIVE: The purpose of this study was to assess the relationship of focal and rotational activations to underlying low-voltage zones (LVZs) (<0.5 mV) and to determine whether there was a temporal (≤500 ms) and spatial (≤12 mm) relationship between these activations. METHODS: Patients undergoing catheter ablation for persistent AF were included. All patients underwent pulmonary vein isolation. Unipolar signals were collected to identify focal and rotational activations using a wavefront propagation algorithm. RESULTS: In 40 patients, 105 activations were identified (57 [54.3%] focal; 48 [45.7%] rotational). Rotational activations were co-localized to LVZs (35/48 [72.9%]) whereas focal activations were not (11/57 in LVZ [19.3%]; P <.001). The proportion of the left atrium occupied by LVZs predicted rotational activations occurrence (area under the curve 0.96; 95% confidence interval 0.90-1.00; P <.001). In patients with a relatively healthy atrium, in which the atrium consisted of ≤15% LVZs, only focal activations were identified. Thirty-two of the 35 rotational activations (91.4%) located in LVZs also showed a temporal and spatial relationship to a focal activation. The presence of a LVZ within 12 mm of the focal activation was a strong predictor for whether a paired rotational activation would also occur in that vicinity. CONCLUSION: Rotational activations are largely confined to areas of structural remodeling and have a clear spatial and temporal relationship with focal activations suggesting they are dependent on them. These novel mechanistic observations outline a plausible model for patient-specific mechanisms maintaining AF.

3.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Article En | MEDLINE | ID: mdl-38258308

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Anti-Infective Agents , Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Middle Aged , Defibrillators, Implantable/adverse effects , Heart Diseases/complications , Anti-Bacterial Agents/therapeutic use , Risk Factors , Electronics , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/prevention & control , Pacemaker, Artificial/adverse effects
4.
JACC Clin Electrophysiol ; 10(1): 121-132, 2024 Jan.
Article En | MEDLINE | ID: mdl-37897463

BACKGROUND: There is a paucity of data comparing vitamin K antagonists (VKAs) to direct oral anticoagulants (DOACs) at the time of cardiac implantable electronic device (CIED) surgery. Furthermore, the best management of DOACs (interruption vs continuation) is yet to be determined. OBJECTIVES: This study aimed to compare the incidence of device-related bleeds and thrombotic events based on anticoagulant type (DOAC vs VKA) and regimen (interrupted vs uninterrupted). METHODS: This was an observational multicenter study. We included patients on chronic oral anticoagulation undergoing CIED surgery. Patients were matched using propensity scoring. RESULTS: We included 1,975 patients (age 73.8 ± 12.4 years). Among 1,326 patients on DOAC, this was interrupted presurgery in 78.2% (n = 1,039) and continued in 21.8% (n = 287). There were 649 patients on continued VKA. The matched population included 861 patients. The rate of any major bleeding was higher with continued DOAC (5.2%) compared to interrupted DOAC (1.7%) and continued VKA (2.1%) (P = 0.03). The rate of perioperative thromboembolism was 1.4% with interrupted DOAC, whereas no thromboembolic events occurred with DOAC or VKA continuation (P = 0.04). The use of dual antiplatelet therapy, DOAC continuation, and male sex were independent predictors of major bleeding on a multivariable analysis. CONCLUSIONS: In this large real-world cohort, a continued DOAC strategy was associated with a higher bleeding risk compared to DOAC interruption or VKA continuation in patients undergoing CIED surgery. However, DOAC interruption was associated with increased thromboembolic risk. Concomitant dual antiplatelet therapy should be avoided whenever clinically possible. A bespoke approach is necessary, with a strategy of minimal DOAC interruption likely to represent the best compromise.


Platelet Aggregation Inhibitors , Thromboembolism , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Anticoagulants/adverse effects , Fibrinolytic Agents , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Thromboembolism/epidemiology , Thromboembolism/prevention & control , Thromboembolism/etiology , Vitamin K , Female
5.
Heart Rhythm O2 ; 4(10): 609-617, 2023 Oct.
Article En | MEDLINE | ID: mdl-37936670

Background: Mechanisms sustaining persistent atrial fibrillation (AF) remain unclear. Objectives: The study sought to evaluate both the clinical outcomes and response to ablation of potential drivers in patients with recurrent persistent AF recurrence following pulmonary vein isolation (PVI). Methods: A total of 100 patients with persistent AF of <2 years' duration underwent cryoballoon PVI (ECGI phenotyping of persistent AF based on driver burden and distribution to predict response to pulmonary vein isolation). Patients with documented recurrence of atrial arrhythmia within 12 months were recruited and underwent repeat PVI (if needed) followed by ablation of potential drivers (PDs) identified by electrocardiographic imaging (ECGI). PDs were defined as rotational activity >1.5 revolutions or focal activations. Cycle lengths were measured pre- and postablation. The primary outcome was freedom from atrial arrhythmia off antiarrhythmic drugs at 1 year as per guidelines. Results: Of 37 patients recruited, 26 had recurrent AF and underwent ECGI-guided ablation of PDs. An average of 6.4 ± 2.7 PDs were targeted per patient. The mean ablation time targeting PDs was 15.5 ± 6.9 minutes. An ablation response occurred in 20 patients (AF termination in 6, cycle length prolongation ≥10% in 14). At 1 year, 14 (54%) of 26 patients were free from arrhythmia, and 12 (46%) of 26 were off antiarrhythmic drugs. Considering the 96 patients who completed follow-up out of the original cohort of 100 patients undergoing cryoablation in this staged strategy, freedom from arrhythmia at 1 year following the last procedure was 72 (75%) of 96, or 70 (73%) of 96 off antiarrhythmic drugs. Conclusions: In patients with recurrent AF despite PVI, ECGI-guided ablation caused an acute response in a majority with reasonable long-term outcomes.

6.
Europace ; 25(11)2023 11 02.
Article En | MEDLINE | ID: mdl-37738643

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Time Factors , Pulmonary Veins/surgery , Catheter Ablation/methods , United Kingdom , Recurrence
7.
Heart Rhythm ; 20(12): 1606-1614, 2023 Dec.
Article En | MEDLINE | ID: mdl-37633429

BACKGROUND: Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and can be challenging to manage. Atrioventricular nodal (AVN) ablation may be an effective management strategy for AF in these patients. OBJECTIVE: The purpose of this study was to assess the efficacy of AVN ablation in HCM patients who have failed medical therapy and/or catheter ablation for AF. METHODS: A multicenter study with retrospective analysis of a prospectively collated HCM registry was performed. AVN ablation patients were identified. Baseline characteristics and device and procedural indications were collected. Symptoms defined by New York Heart Association and European Heart Rhythm Association classification and echocardiographic findings during follow-up were assessed. RESULTS: Fifty-nine patients were included in the study. Indications for AVN ablation were 6 (10.2%) inappropriate implantable cardioverter-defibrillator shock, 35 (59.3%) ineffective rate control, and 18 (30.5%) to regularize rhythm for symptom improvement. During post-AVN ablation follow-up of 79.4 ± 61.1 months, left ventricular ejection fraction (LVEF) remained stable (pre-LVEF 48.9% ± 12.6% vs post-LVEF 50.1% ± 10.1%; P = .29), even in those without a cardiac resynchronization therapy (CRT) device (pre-LVEF 54.3% ± 8.0% vs post-LVEF 53.8% ± 8.0%; P = .65). Forty-nine patients (83.1%) reported an improvement in symptoms regardless of AF type (17/21 [81.0%] paroxysmal vs 32/38 [84.2%] persistent; P = 1.00), presence of baseline left ventricular impairment (22/26 [84.6%] LVEF ≤50% vs 27/33 [81.8%] LVEF ≥50%; P = 1.00) or CRT device (27/32 [84.4%] CRT vs 22/27 [81.5%] no CRT; P = 1.00). Symptoms improved in 16 patients (89.0%) who underwent AVN ablation to regularize rhythm. CONCLUSION: AVN ablation improved symptoms without impacting left ventricular function in the majority of patients. The data suggest that AVN ablation is an effective and safe management approach for AF in HCM and should be further evaluated in larger prospective studies.


Atrial Fibrillation , Cardiomyopathy, Hypertrophic , Catheter Ablation , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrioventricular Node/surgery , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/therapy , Prospective Studies , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left
8.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1500-1512, 2023 08.
Article En | MEDLINE | ID: mdl-37204357

BACKGROUND: Optimal method for voltage assessment in AF remains unclear. OBJECTIVES: This study evaluated different methods for assessing atrial voltage and their accuracy in identifying pulmonary vein reconnection sites (PVRSs) in atrial fibrillation (AF). METHODS: Patients with persistent AF undergoing ablation were included. De novo procedures: voltage assessment in AF with omnipolar voltage (OV) and bipolar voltage (BV) methodology and BV assessment in sinus rhythm (SR). Activation vector and fractionation maps were reviewed at voltage discrepancy sites on OV and BV maps in AF. AF voltage maps were compared with SR BV maps. Repeat ablation procedures: OV and BV maps in AF were compared to detect gaps in wide area circumferential ablation (WACA) lines that correlated with PVRS. RESULTS: Forty patients were included: 20 de novo and 20 repeat procedures. De novo procedure: OV vs BV maps in AF; average voltage 0.55 ± 0.18 mV vs 0.38 ± 0.12 mV; P = 0.002, voltage difference of 0.20 ± 0.07 mV; P = 0.003 at coregistered points and proportion of left atrium (LA) area occupied by low-voltage zones (LVZs) was smaller on OV maps (42.4% ± 12.8% OV vs 66.7% ± 12.7% BV; P < 0.001). LVZs identified on BV maps and not on OV maps correlated frequently to wavefront collision and fractionation sites (94.7%). OV AF maps agreed better with BV SR maps (voltage difference at coregistered points 0.09 ± 0.03 mV; P = 0.24) unlike BV AF maps (0.17 ± 0.07 mV, P = 0.002). Repeat ablation procedure: OV was superior in identifying WACA line gaps that correlated with PVRS than BV maps (area under the curve = 0.89, P < 0.001). CONCLUSIONS: OV AF maps improve voltage assessment by overcoming the impact of wavefront collision and fractionation. OV AF maps correlate better with BV maps in SR and more accurately delineate gaps on WACA lines at PVRS.


Atrial Fibrillation , Catheter Ablation , Humans , Cicatrix/pathology , Electrophysiologic Techniques, Cardiac/methods , Catheter Ablation/methods , Heart Atria
9.
Europace ; 25(5)2023 05 19.
Article En | MEDLINE | ID: mdl-37213071

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients develop ventricular arrhythmias (VAs) responsive to anti-tachycardia pacing (ATP). However, VA episodes have not been characterized in accordance with the device therapy, and with the emergence of the subcutaneous implantable cardioverter defibrillator (S-ICD), the appropriate device prescription in ARVC remains unclear. Study aim was to characterize VA events in ARVC patients during follow-up in accordance with device therapy and elicit if certain parameters are predictive of specific VA events. METHODS AND RESULTS: This was a retrospective single-centre study utilizing prospectively collated registry data of ARVC patients with ICDs. Forty-six patients were included [54.0 ± 12.1 years old and 20 (43.5%) secondary prevention devices]. During a follow-up of 12.1 ± 6.9 years, 31 (67.4%) patients had VA events [n = 2, 6.5% ventricular fibrillation (VF), n = 14], 45.2% VT falling in VF zone resulting in ICD shock(s), n = 10, 32.3% VT resulting in ATP, and n = 5, 16.1% patients had both VT resulting in ATP and ICD shock(s). Lead failure rates were high (11/46, 23.9%). ATP was successful in 34.5% of patients. Severely impaired right ventricular (RV) function was an independent predictor of VT resulting in ATP (hazard ratio 16.80, 95% confidence interval 3.74-75.2; P < 0.001) with a high predictive accuracy (area under the curve 0.88, 95%CI 0.76-1.00; P < 0.001). CONCLUSION: VA event rates are high in ARVC patients with a majority having VT falling in the VF zone resulting in ICD shock(s). S-ICDs could be of benefit in most patients with ARVC with the absence of severely impaired RV function which has the potential to avoid consequences of the high burden of lead failure.


Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Adult , Middle Aged , Aged , Defibrillators, Implantable/adverse effects , Retrospective Studies , Ventricular Function, Right , Follow-Up Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/prevention & control , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/prevention & control , Arrhythmias, Cardiac/etiology , Cardiomyopathies/complications , Adenosine Triphosphate , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/therapy
10.
Front Cardiovasc Med ; 10: 1110165, 2023.
Article En | MEDLINE | ID: mdl-37051067

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

11.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Article En | MEDLINE | ID: mdl-36808788

INTRODUCTION: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND RESULTS: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort. CONCLUSIONS: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Heart Rate , Pulmonary Veins/surgery , Prospective Studies , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome , Recurrence
12.
Eur J Heart Fail ; 25(1): 77-86, 2023 01.
Article En | MEDLINE | ID: mdl-36221809

AIMS: The ARC-HF and CAMTAF trials randomized patients with persistent atrial fibrillation (AF) and heart failure (HF) to early routine catheter ablation (ER-CA) versus pharmacological rate control (RC). After trial completion, delayed selective catheter ablation (DS-CA) was performed where clinically indicated in the RC group. We hypothesized that ER-CA would result in a lower risk of cardiovascular hospitalization and death versus DS-CA in this population. METHODS AND RESULTS: Overall, 102 patients were randomized (age 60 ± 11 years, left ventricular ejection fraction [LVEF] 31 ± 11%): 52 to ER-CA and 50 to RC. After 12 months, patients undergoing ER-CA had improved self-reported symptom scores, lower New York Heart Association class (i.e. better functional capacity), and higher LVEF compared to patients receiving RC alone. During a median follow-up of 7.8 (interquartile range 3.9-9.9) years, 27 (54%) patients in the RC group underwent DS-CA and 34 (33.3%) patients died, including 17 (32.7%) randomized to ER-CA and 17 (34.0%) randomized to RC. Compared with DS-CA, a strategy of ER-CA exhibited similar risk of all-cause mortality (adjusted hazard ratio [aHR] 0.89, 95% confidence interval [CI] 0.44-1.77, p = 0.731) and combined all-cause mortality or cardiovascular hospitalization (aHR 0.80, 95% CI 0.43-1.47, p = 0.467). However, analyses according to treatment received suggested an association between CA and improved outcomes versus RC (all-cause mortality: aHR 0.43, 95% CI 0.20-0.91, p = 0.028; all-cause mortality/cardiovascular hospitalization: aHR 0.48, 95% CI 0.24-0.94, p = 0.031). CONCLUSIONS: In patients with persistent AF and HF, ER-CA produces similar long-term outcomes to a DS-CA strategy. The association between CA as a treatment received and improved outcomes means there is still a lack of clarity regarding the role of early CA in selected patients. Randomized trials are needed to clarify this question.


Atrial Fibrillation , Catheter Ablation , Heart Failure , Ventricular Dysfunction, Left , Humans , Middle Aged , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Ventricular Dysfunction, Left/drug therapy , Catheter Ablation/methods
13.
J Cardiovasc Electrophysiol ; 33(11): 2263-2273, 2022 11.
Article En | MEDLINE | ID: mdl-35924481

BACKGROUND: This prospective trial sought to phenotype persistent atrial fibrillation (AF) based on AF mechanisms using electrocardiographic imaging (ECGI) mapping to determine whether this would predict long-term freedom from arrhythmia after pulmonary vein isolation (PVI). METHODS: Patients with persistent AF of <2 years duration underwent cryoballoon PVI. ECGI mapping was performed before PVI to determine potential drivers (PDs) defined as rotational activations completing ≥1.5 revolutions or focal activations. The coprimary endpoint was the association between (1) PD burden (defined as the number of PD occurrences) and (2) PD distribution (defined as the number of segments on an 18-segment model of the atria harboring PDs) with freedom from arrhythmia at 1-year follow up. RESULTS: Of 100 patients, 97 completed follow up and 52 (53.6%) remained in sinus rhythm off antiarrhythmic drugs. Neither PD burden nor PD distribution predicted freedom from arrhythmia (hazard ratio [HR]: 1.01, 95% confidence interval [CI]: 0.99-1.03, p = .164; and HR: 1.04, 95% CI: 0.91-1.17, p = .591, respectively). Otherwise, the burden of rotational PDs, rotational stability, and the burden of PDs occurring at the pulmonary veins and posterior wall all failed to predict arrhythmia recurrence (all p > .10). CONCLUSIONS: AF mechanisms as determined using ECGI mapping do not predict outcomes after PVI for persistent AF. Further studies using different methodologies to characterize AF mechanisms are warranted (NCT03394404).


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Prospective Studies , Recurrence , Treatment Outcome , Electrocardiography , Phenotype , Catheter Ablation/adverse effects , Catheter Ablation/methods
14.
Europace ; 24(11): 1824-1833, 2022 11 22.
Article En | MEDLINE | ID: mdl-35894862

AIMS: To determine the incidence, clinical features, management, and outcomes of pacemaker (PM) and implantable cardioverter-defibrillator (ICD) lead cardiac perforation. Cardiac perforations due to PM and ICD leads are rare but serious complications. Clinical features vary widely and may cause diagnostic delay. Management strategies are non-guideline based due to paucity of data. METHODS AND RESULTS: A multicentre retrospective series including 3 UK cardiac tertiary centres from 2016 to 2020. Patient, device, and lead characteristics were obtained including 6-month outcomes. Seventy cases of perforation were identified from 10 631 procedures; perforation rate was 0.50% for local implants. Thirty-nine (56%) patients were female, mean ( ± standard deviation) age 74 ( ± 13.8) years. Left ventricular ejection fraction 51 ( ± 13.2) %. Median time to diagnosis was 9 (range: 0-989) days. Computed tomography (CT) diagnosed perforation with 97% sensitivity. Lead parameter abnormalities were present in 86% (whole cohort) and 98.6% for perforations diagnosed >24 h. Chest pain was the commonest symptom, present in 46%. The management strategy was percutaneous in 98.6% with complete procedural success in 98.6%. Pericardial effusion with tamponade was present in 17% and was associated with significantly increased mortality and major complications. Anticoagulation status was associated with tamponade by multivariate analysis (odds ratio 21.7, 95% confidence interval: 1.7-275.5, P = 0.018). CONCLUSIONS: Perforation was rare (0.50%) and managed successfully by a percutaneous strategy with good outcomes. Tamponade was associated with increased mortality and major complications. Anticoagulation status was an independent predictor of tamponade. Case complexity is highly variable and requires skilled operators with a multi-disciplinary approach to achieve good outcomes.


Defibrillators, Implantable , Heart Injuries , Pacemaker, Artificial , Humans , Female , Aged , Male , Retrospective Studies , Stroke Volume , Delayed Diagnosis/adverse effects , Ventricular Function, Left , Pacemaker, Artificial/adverse effects , Heart Injuries/diagnostic imaging , Heart Injuries/etiology , Heart Injuries/therapy , Defibrillators, Implantable/adverse effects , Iatrogenic Disease , Anticoagulants
15.
J Cardiovasc Electrophysiol ; 33(10): 2139-2151, 2022 10.
Article En | MEDLINE | ID: mdl-35775822

INTRODUCTION: Markers predicting atrial fibrillation (AF) termination and freedom from AF/atrial tachycardia (AT) has been proposed. This study aimed to evaluate the role of novel coronary sinus (CS) electrogram characteristics in predicting the acute ablation response and freedom from AF/AT during follow-up. METHODS: Patients undergoing ablation for persistent AF as part of the Stochastic Trajectory Analysis of Ranked signals mapping study were included. Novel CS electrogram characteristics including CS cycle length variability (CLV) and CS activation pattern stability (APS) and proportion of low voltage zones (LVZs) were reviewed as potential predictors for AF termination on ablation and freedom from AF/AT during follow-up. The relationship between localized driver characteristics and CS electrogram characteristics was also assessed. RESULTS: Sixty-five patients were included. AF termination was achieved in 51 patients and 80% of patients were free from AF/AT during a follow-up of 29.5 ± 3.7 months. CS CLV of <30 ms, CS APS of ≥30% and proportion of LVZ < 30% showed high diagnostic accuracy in predicting AF termination on ablation and freedom from AF/AT during follow-up (CS CLV odds ratio [OR] 25.6, area under the curve [AUC] 0.91; CS APS OR 15.9, AUC 0.94; proportion of LVZs OR 21.4, AUC 0.88). These markers were independent predictors of AF termination on ablation and AF/AT recurrence during follow-up. Ablation of a smaller number of drivers that demonstrate greater dominance strongly correlate with greater CS organization. CONCLUSION: Novel CS electrogram characteristics were independent predictors of AF termination and AF/AT recurrence during follow-up. These markers can potentially aid in predicting outcomes and guide ablation and follow-up strategies.


Atrial Fibrillation , Catheter Ablation , Coronary Sinus , Pulmonary Veins , Tachycardia, Supraventricular , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Coronary Sinus/surgery , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
16.
Europace ; 24(9): 1420-1429, 2022 10 13.
Article En | MEDLINE | ID: mdl-35737685

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Adenosine , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Benchmarking , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
17.
JACC Clin Electrophysiol ; 8(4): 426-436, 2022 04.
Article En | MEDLINE | ID: mdl-35450597

OBJECTIVES: This study sought to assess the association between electrocardiographic imaging (ECGI) parameters and voltage from simultaneous electroanatomic mapping (EAM). BACKGROUND: ECGI offers noninvasive assessment of electrophysiologic features relevant for mapping ventricular arrhythmia and its substrate, but the accuracy of ECGI in the delineation of scar is unclear. METHODS: Sixteen patients with structural heart disease underwent simultaneous ECGI (CardioInsight, Medtronic) and contact EAM (CARTO, Biosense-Webster) during ventricular tachycardia catheter ablation, with 7 mapped epicardially. ECGI and EAM geometries were coregistered using anatomic landmarks. ECGI points were paired to the closest site on the EAM within 10 mm. The association between EAM voltage and ECGI features from reconstructed epicardial unipolar electrograms was assessed by mixed-effects regression models. The classification of low-voltage regions was performed using receiver-operating characteristic analysis. RESULTS: A total of 9,541 ECGI points (median: 596; interquartile range: 377-737 across patients) were paired to an EAM site. Epicardial EAM voltage was associated with ECGI features of signal fractionation and local repolarization dispersion (N = 7; P < 0.05), but they poorly classified sites with bipolar voltage of <1.5 mV or <0.5 mV thresholds (median area under the curve across patients: 0.50-0.62). No association was found between bipolar EAM voltage and low-amplitude reconstructed epicardial unipolar electrograms or ECGI-derived bipolar electrograms. Similar results were found in the combined cohort (n = 16), including endocardial EAM voltage compared to epicardial ECGI features (n = 9). CONCLUSIONS: Despite a statistically significant association between ECGI features and EAM voltage, the accuracy of the delineation of low-voltage zones was modest. This may limit ECGI use for pr-procedural substrate analysis in ventricular tachycardia ablation, but it could provide value in risk assessment for ventricular arrhythmias.


Heart Diseases , Tachycardia, Ventricular , Electrocardiography/methods , Endocardium , Epicardial Mapping/methods , Humans , Tachycardia, Ventricular/surgery
18.
Heart Rhythm ; 19(6): 875-884, 2022 06.
Article En | MEDLINE | ID: mdl-35134548

BACKGROUND: Mechanisms sustaining persistent atrial fibrillation (AF) remain uncertain. OBJECTIVES: The purpose of this study was to use electrocardiographic imaging (ECGI) mapping to guide localized driver ablation in patients with persistent AF. METHODS: Patients undergoing catheter ablation for persistent AF <2 years were included. Patients were enrolled consecutively between 2018 and 2020. ECGI mapping was used to identify focal and rotational potential drivers (PDs). PDs were ablated after pulmonary vein isolation (PVI). The ablation response and freedom from AF/atrial tachycardia (AT) at 1 year were assessed. RESULTS: Forty patients were enrolled. AF terminated with PVI in 8 patients, and 32 underwent ECGI-guided driver ablation. Average procedural duration was 228.8 ± 66.7 minutes, with a total radiofrequency delivery time of 38.9 ± 14.1 minutes. During 1 year of follow-up, the primary endpoint of freedom from AF/AT was achieved in 26 patients (65%). The secondary endpoint of freedom from AF was achieved in 30 patients (75%). AF termination was achieved in 20 of 40 patients (50%). The composite endpoint of an ablation response (AF termination or cycle length slowing ≥10%) occurred in 37 of 40 patients (92.5%). In total, 181 drivers (48 focal and 133 rotational) were ablated, with an ablation response achieved in 59 (32.6%). Focal drivers and drivers with a higher recurrence rate and greater temporal stability were more likely to be associated with an ablation response including AF termination (P <.001). CONCLUSION: ECGI-guided ablation plus PVI results in high freedom from AF during follow-up and an ablation response in a large proportion of patients. Using driver type and characteristics may facilitate a hierarchical ablation approach.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Rate/physiology , Humans , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
19.
Pacing Clin Electrophysiol ; 45(3): 365-373, 2022 Mar.
Article En | MEDLINE | ID: mdl-35023176

BACKGROUND: The risk factors for developing pacing induced left ventricular dysfunction (LVD) in patients with high burden of right ventricular pacing (RVP) is poorly understood. Therefore, in the present study, we aimed to assess the determinants of pacing induced LVD. METHODS: Our data were retrospectively collected from 146 patients with RVP > 40% who underwent generator change (GC) or cardiac resynchronization therapy (CRT) upgrade between 2016 and 2019 who had left ventricular ejection fraction (EF) ≥50% at initial implant. RESULTS: A total of 75 patients had CRT upgrade due to pacing induced LVD (EF < 50%) and 71 patients with preserved LV function (EF ≥ 50%) had a GC. Primary indication for pacing in both groups was complete heart block. Male predominance (p = .008), prior myocardial infarction (MI) (p = .001), atrial fibrillation (AF) (p = .009), chronic kidney disease (CKD) (p = .005), and borderline low systolic function (BLSF) (EF 50%-55%) (p = .04) were more prevalent in the CRT upgrade group. Presence of AF (odds ratio [OR] = 3.05, 95% confidence interval [CI] 1.42-6.58; p = .004), BLSF (OR = 3.8, 95% CI 1.22-11.8; p = .02), and male gender (OR = 2.41, 95% CI 1.14-5.08; p = .02) were independent predictors for RVP induced LVD. Age (OR = 1.08, 95% CI 1.02-1.14; p = .005) and BLSF (OR = 5.33, 95% CI 1.26-22.5; p = .023) were independent predictors of earlier development of LVD after implant. CONCLUSIONS: Our results suggested that AF, BLSF, and male gender are predictors for development of pacing induced LVD in patients with high RVP burden. LVD can occur at any time after pacemaker implant with BLSF and increasing age associated with earlier development of LVD.


Atrial Fibrillation , Cardiac Resynchronization Therapy , Heart Failure , Ventricular Dysfunction, Left , Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/methods , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Female , Heart Failure/therapy , Humans , Male , Retrospective Studies , Risk Factors , Stroke Volume , Treatment Outcome , United Kingdom/epidemiology , Ventricular Function, Left
20.
Heart Rhythm O2 ; 3(6Part A): 631-638, 2022 Dec.
Article En | MEDLINE | ID: mdl-36589910

Background: Recent studies suggest persistent atrial fibrillation (AF) is maintained by localized focal or rotational electrical activations termed drivers. Objective: The purpose of this study was to evaluate how left atrial (LA) dilation and time in AF impact persistent AF mechanisms. Methods: Patients with persistent AF <2 years underwent electrocardiographic image mapping. Potential drivers (PDs) were defined as rotational wavefront activity ≥1.5 revolutions or focal activations. Distribution of PDs was recorded using an 18-segment model. Results: One hundred patients were enrolled (age 61.3 ± 12.1 years). Of these patients, 47 were hypertensive, 14 had diabetes mellitus, and 10 had ischemic heart disease. AF duration was 8 [5-15] months. Median LA diameter was 39 [33-43] mm. Although LA dimensions did not correlate with overall PD burden or distribution, there was a modest correlation between increasing LA area (r = 0.235; P = .024) and LA volume (r = 0.216; P = .039) with proportion of PDs that were rotational. Although time in AF did not correlate with overall PD burden or distribution, there was a correlation between time in AF and the number of focal PDs (r = 0.203; P = .044). Female gender, increasing age, and hypertension also were associated with an increase in focal PDs. Conclusion: This is the first study to demonstrate different AF mechanisms in patient subgroups. Greater understanding of patient-specific AF mechanisms may facilitate a tailored approach to AF mapping and ablation.

...